IMR Environmental Equipment, Inc.

CONTINUOUS FLUE-GAS ANALYZING SYSTEM
IMR 5000


 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

IMR 5000 P
CONTINUOUS FLUE-GAS MONITORING SYSTEM

The IMR 5000 is a state-of-the-art continuous flue-gas monitoring system, and  is designed for a wide variety of flue-gas monitoring applications.
The IMR 5000 is a stand-alone analyzer that  works 
automatically. The rugged wall mounted enclosure meets NEMA type 4X (IP65) standards.
The modular approach of the IMR 5000 allows one
or more gases (up to 8) to be measured simultaneously.
The IMR 5000 uses the latest sensor technology from electro-chemical sensors up to NDIR benches.
The system can analyze samples taken from up to 4 different sampling points. This sequential measurement 
is only possible with the addition of multiple gas 
sampling and conditioning devices (IMR 400).
The IMR 5000 offers various outputs such as a serial interface (RS232/RS485), an analog output (volts / current) and an alarm (relay). 
All of the above features allow the IMR 5000 to be configured for a variety of applications and can easily be upgraded in the future.

IMR 5000 - GAS-SAMPLING PROBE

IMR-5000


FEATURES APPLICATIONS
  • Up to eight different controllers
  • Up to 4 different sampling points
  • Analog output (volt/current)
  • Alarm output
  • RS232/RS485 digital output
  • Built to customer specifications
  • Rugged and weather-resistant
  • Large display
  • Easy to use and easy to service
  • Latest sensor technology
  • Boiler / Burner 
  • Turbines
  • Engines
  • Incinerators
  • Process control
  • Landfills
  • Cogeneration plants


 



IMR 5000 - 3-CONTROLLERS

IMR 5000 - APPLICATION EXAMPLE
One of our most popular systems is the IMR 5000 in combination with the IMR 400. 
The IMR 400 is a gas conditioning system that cleans and dries the flue-gas. 
Please click here to find out more about the IMR 400.

Function diagram

IMR 5000 (3-controllers HC, CO, CO2) with 1x IMR 400

The IMR 400 is equipped with a flange-mounted, gas-sampling probe and a heated hose. 
Either a 'peltier cooler' or a 'permeation dryer' is used to dry the flue-gas.
The conditioned flue-gas is then analyzed by the IMR 5000.
Individual sensors (NDIR) measure HC, CO and CO2. The alarm outputs and analog outputs
can be configured individually and are fully scalable across the measurement range.



More examples:
IMR 5000 (3-controllers) with 2x IMR 400 IMR 5000 (2-controllers) with 3x IMR 400

The IMR 5000 is a versatile instrument that can be customized for the customers specific needs. 
The flue-gas analyzing system can be equipped with up to 8 different controller systems and can measure
up to different 4 stacks.
Please contact us for any special configuration.


Block diagram
IMR 5000 (3-controllers HC, CO, CO2) with 1x IMR 400
The IMR 5000 is equipped with various solenoids and relays. These components make sure that the unit operates 
automatically. The calibration of the unit is quite simple. Each controller gets adjusted  individually by applying a 
test gas on the specific calibration fitting.

IMR 5000 - DISPLAY

Green

Amber

Red
Each controller has its own display. The height of the LED is 0.83" (21mm) and the color is programmable at any
set point (red, green and amber).

IMR 5000 - OUTPUT FORMATS
Analog output
Each controller has one individual analog output and each output maybe configured from the display at any time. 
The outputs are fully scalable across the measurement range.
Format:   0..20mA   /   4..20mA   /   0-1VDC   /   0-10VDC

Alarms (Relay)
Each controller  has one individual relay (SPDT). Each relay and its different modes and levels of activation can be configured from the display at any time.
Operation: 
Absolute/deviation, latched/unlatched, normally open/normally closed, above/below, high/low, band 


PROCESS CONTROLLERS WITH SENSORS / TRANSMITTERS
Please click on the specific sensor for the data sheet.
Any ranges can be specified between the minimum and maximum ranges stated below. 
In general any eight channels can be fitted to the system. 
Other sensors, measurement ranges and limitations regarding combinations are available upon request.
 
PARAMETER PRINCIPLE PART NO. RANGES
O2 Oxygen Electro-chemical  50050 0-25% to  0-100%
O3 Ozone Electro-chemical  50075 0-2 to 0-100ppm 
CO Carbon monoxide Electro-chemical  50110 0-500ppm to  0-9,999ppm / 0-1% to 0-10%
CO Carbon monoxide NDIR 50100 0-5% to  0-10% 
CO2 Carbon dioxide NDIR  50150 0-2,000ppm to  0-100%
CH4 Methane NDIR  50850 0-9,999ppm to  0-30%
HC Hydrocarbons NDIR 50800 0-9,999ppm to 0-30% 
HC Hydrocarbons Pellistor 50810  0-100% LEL
NO Nitric oxide Electro-chemical 50200 0-1,000ppm to 0-5,000ppm 
NO2 Nitrogen dioxide Electro-chemical 50500 0-100ppm to  0-500ppm
SO2 Sulfur dioxide Electro-chemical 50400 0-2,000ppm to 0-4,000ppm
H2S Hydrogen sulfide Electro-chemical 50600 0-100ppm to 0-500ppm
HCl Hydrogen chloride Electro-chemical 50900 0-100ppm to 0-200ppm 
H2 Hydrogen Electro-chemical 50650 0-1,000ppm to 0-2%
Cl2 Chlorine Electro-chemical 50950 0-20ppm
NH3 Ammonia Electro-chemical 50925 0-50ppm to 0-200ppm
Flue-gas temperature Type K 50675  0-1200°C 

IMR 5000 - SPECIFICATION
Display Each controller; 4-digit, 9-segment LED, 0.83" (21mm)
Red, green and amber programmable colors for process variable
Modes Time and Amplitude proportional control modes; selectable manual or auto PID, proportional with integral
Damping 0000 to 0008
Soak 00.00 to 99.59, or OFF
Ramp to Setpoint 00.00 to 99.59, or OFF
Relay 250VAC or 30VDC @ 3A; configurable for on/off, PID and Ramp and Soak
Output SPDT type
SSR 20-265VAC @ 0.05-0.5A (resistive load); continuous
DC pulse Non-isolated; 10VDC @ 20mA
Analog output: Non-isolated, proportional 0 to 10VDC or 0 to 20mA; 500Ohm max
Communications Optional; RS232 or RS485; 300 to 19.2 K baud
Power supply: 120VAC/60Hz or 240VAC/50Hz
Enclosure
 

 

Wall mounted, NEMA4/IP65
Dimensions in inch (mm): 
18.3 (465) x 13.8 (350) x 7.9 (200) (up to 2 controller)
27.6 (700) x 19.7 (500) x 9.8 (250) (up to 4 controller)
55.1 (1400) x 29.5 (750) x 14.7 (375) ( up to 8 controller)
Operating temperature 50°F to 104°F (10°C to  40°C) 
Storage temperature -4°F to 122°F (-20°C to 50°C)
Operating environment 90% RH non-condensing

Please contact us for further product information: Info@IMRUSA.COM

IMR Environmental Equipment, Inc.
3634 Central Ave.  -  St. Petersburg, FL 33711 USA
Phone: 727/328-2818  -  Toll free: 1-800-746-4467
Fax: 727/328-2826
© Copyright 2001 IMR Environmental Equipment, Inc.