THE ALL NEW
IMR 2000P / 2800P
NEW
FEATURES FOR THE IMR 2000 Series
Latest sensor technology for more a accurate
measurement and a longer life
time
Improved interior design for easier service
and better unit protection
Measures and calculates optional up to 8 gases
Larger display for better reading
Increased memory
IMR-2800P
|
IMR 2800P
|
| FEATURES |
|
Portable combustion gas analyzer housed in a rugged
aluminum case |
|
Simultaneous measurement of
| O2 Oxygen |
NO2 Nitric dioxide (IMR 2800) |
| CO Carbon Monoxide |
SO2 Sulfur dioxide |
| NO Nitric oxide |
TG Flue gas temperature |
| TA Ambient air temperature |
|
|
|
Calculation of following parameters
| Losses |
Excess Air |
| CO2 Carbon Dioxide |
|
|
|
23 Fuels are programmed – 4 fuels are programmable |
|
Automatic zero calibration |
|
Integrated self check program |
|
Simultaneous display of 6 parameters on the illuminated
display |
|
Printer with programmable print-out cycles |
|
Standard deviation and average value calculation |
|
Draft measurement |
|
Unit selection : ppm - mg - mg(ref O2) |
|
Gas sampling probe E – length 0.8ft (250mm) , hose
8ft (2.5m) |
|
Rechargeable battery with charger |
|
Power supply 110VAC/60Hz or 230VAC/50Hz |
|
| OPTIONAL
FEATURES |
|
HC or H2S measurement |
|
Prepared for high temperature measurement
(up to 2732 F) |
|
Gas sampling probes with different lengths |
|
Soot measurement |
|
| THE ALL NEW IMR 2000 / 2800 |
|
TECHNICAL
DATA
| PARAMETER |
PRINCIPLE |
RESOLUTION |
ACCURACY |
RANGE |
STANDARD |
| O2 Oxygen |
Electro-chemical |
0.1 Vol.% |
± 0.2 % |
0-20.9Vol. % |
ü
|
| CO Carbon monoxide |
Electro-chemical |
1 ppm |
5 % |
0-2,000ppm |
ü
|
| NO Nitric oxide |
Electro-chemical |
1 ppm |
5 % |
0-2,000 ppm |
ü |
| SO2 Sulfur dioxide |
Electro-chemical |
1 ppm |
5 % |
0-4,000 ppm |
ü |
| NO2 Nitric dioxide |
Electro-chemical |
1
ppm |
5
% |
0-100
ppm |
IMR 2800 |
| H2S Hydrogen Sulfide |
Electro-chemical |
1
ppm |
5
% |
0-200
ppm |
|
| HC Hydrocarbons |
|
0.1
% |
5
% |
0-100
% LEL |
|
| TG Flue gas temperature |
NiCr-Ni thermocouple |
1 K |
± 2 % |
-4° F / 2192° F
-20°C
/ 1200°C |
ü
|
| TA Air temperature |
Semiconductor |
1 K |
± 0.5 K |
-4° F / 248° F
-20°C
/ 120°C |
ü |
| P Draft |
Solid state |
0.004" H2O
0.01 hPa |
± 2 % |
-8" / 8" H2O
-20 / 20 hPA |
ü |
| CO2 Carbon dioxide |
Calculation |
0.1 Vol.% |
± 0.2 % |
0- CO2 max |
ü
|
| Losses / qA |
Calculation |
1 % |
± 0.5 % |
0-999 % |
ü
|
| Excess Air/ LAMBDA |
Calculation |
1 % |
± 2 % |
0-999 % |
ü
|
| Soot |
Filter paper method |
|
|
|
|
Other measurement ranges are available
upon request
Equipped with max. 8 sensors |
| SPECIFICATION |
| Dimensions wxdxh: 15"(315mm) x 6.5"(185mm) x 12.4"(380mm) |
Weight:
IMR 2000: approx. 16lbs. (7.5kg)
IMR 2800: approx. 17lbs. (8kg) |
| MODEL |
PART-NO. |
| IMR 2000P
O2, CO, NO, SO2 |
20000 |
| IMR 2800P
O2, CO, NO, SO2, NO2 |
28000 |
|
|
IMR Environmental Equipment, Inc. reserves the right to
adopt technical modifications without prior notice
IMR Environmental Equipment, Inc.
3634 Central Ave. - St. Petersburg, FL
33711 USA
Phone: 727/328-2818 - Toll free: 1-800-746-4467
Fax: 727/328-2826
Email: Info@imrusa.com
© Copyright
2001 IMR Environmental Equipment, Inc. |