COMBUSTION GAS ANALYZER
IMR 1400



 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

IMR-1400-P/PL

IMR-1400-PS

IMR Environmental Equipment -IMR 1400

IMR 1400
Portable, continuous measuring flue gas analysis instrument housed in an aluminum case for measuring air temperature, flue gas temperature, Oxygen O2, Carbon monoxide CO (H2 comp.), Nitric oxide NO, Nitric dioxide NO2, Sulfur dioxide SO2, Hydrocarbon HC, losses, excess air, combustion efficiency, draft, Carbon dioxide CO2 and soot. Simultaneous display of eight measured parameters on the illuminated LCD. Integrated thermal printer and RS232 interface. Measurement printout or service printout, both include date,time and fuel type. ppm,mg,mg/kWh,mg(ref.O2) units are selectable. Automatic and manual CO-bypass. 
Memory for 220 measurements. Case has additional space for spare parts.
IMR Environmental Equipment - IMR 1400 P/PL/PS

STANDARD EQUIPMENT
Illuminated display with simultaneous display of 8 measured variables Printout of all measured and calculated parameters Gas sampling probe, length 10.5" (270mm),NiCrNi, flexible hose 11.5 ft. (3,5m)
Languages: D, UK, F, USA, E, TR, etc. Electronic controlled soot measurement  Combustion air probe, length 5" (130mm), line 11.5 ft. (3,5m)
7 programmed and 5 programmable fuels Automatic and manual CO overflow shut-off Condensation trap with integrated filter
Measurement display is switchable between ppm, mg, mg(O2) and mg/kwh Automatic zero calibration within 3 minutes. Recalibration within 30 sec. Operating temperature 50°F..104°F (10°C..40°C)
Battery status is shown on the measurement display Integrated self check program for all functions and parameters. Storing temperature -4°F..122°F (-20°C..50°C)
Interface RS 232 After 1000 operating hours a "Service needed" note appears on the display. Power supply  230V/50Hz, 110V/60Hz, 12VDC

TECHNICAL DATA
PARAMETER  PRINCIPLE RESOLUTION ACCURACY RANGE  1400 P
O2 Oxygen Electro-chemical 0.1 Vol.% ± 0.2 % 0-20.9Vol. %
ü
CO Carbon monoxide Electro-chemical 1 ppm 5 %  0-2,000 ppm
ü
COp Carbon monoxide-corrected Calculation 1 ppm 5 %    ü
NO Nitric oxide Electro-chemical 1 ppm 5 % 0-2,000 ppm
1400PL/PS
NO2 Nitric dioxide Electro-chemical 1 ppm 5 % 0- 100 ppm  
SO2 Sulfur dioxide Electro-chemical 1 ppm 5 % 0-4,000 ppm
1400PS
HC Hydrocarbon   0.1%  5 % 0-100% LEL  
TG Gas temperature NiCr-Ni thermocouple 1 K ± 2 % -4°F..2192°F
-20°C..1200°C
ü
TA Air temperature Semiconductor 1 K ± 0.5 K 4°F..248°F
-20°C..120°C
ü
P Draft Solid state 0.004" H2O
0.01 hPa
± 2 % -12"H2O/+20"H2O
-30hPa/+50hPa
ü
CO2 Carbon dioxide Calculation 0.1 Vol.% ± 0.2 % 0- CO2 max
ü
Combustion Efficiency / ETA Calculation 1 % ± 0.5 % 0-99,9 %
ü
Losses / qA  Calculation 1 % ± 0.5 % 0-99,9 %
ü
Excess air / LAMBDA Calculation 1 % ± 2 % 1,0-9,99
ü
Soot Filter paper      
ü
Other ranges are available upon request.
4 sensors are the maximum for the IMR 1400 PS (4th sensor can be specified)

SPECIFICATION
Dimensions wxdxh: 16"(425mm) x 7"(185mm) x 11"(290mm)
Weight: approx. 15lbs. (5.8kg)

MODEL PART-NO.
IMR 1400 P       O2, CO 14280
IMR 1400 PL    O2,CO, NO 14290
IMR 1400 PS    O2, CO, NO, SO2
(NO2 or HC instead of SO2)
14295

IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice


IMR Environmental Equipment, Inc.