| STANDARD
FEATURES |
|
Portable and very compact combustion gas analyzer housed
in a rugged aluminum case |
|
Measurement of:
O2 Oxygen, CO Carbon Monoxide,
TG Flue-gas temperature,NO Nitric oxide(14090/14190) |
|
ASME/BImSchV - Calculation:
Combustion efficiency,Losses,Excess Air,
CO2 Carbon Dioxide |
|
7 Fuels are programmed – 5 fuels are programmable |
|
Automatic zero calibration |
|
Integrated self check program |
|
Simultaneous display of eight parameters on the
illuminated display |
|
Unit selection : ppm - mg - mg(ref O2) –
mg/kWh |
|
Gas sampling probe E – length 0.8 ft (250mm) , hose
8 ft (2.5m) |
|
Rechargeable battery |
|
Thermal printer (14100 / 14190) |
|
Power supply 110VAC/60Hz or 230VAC/50Hz |
|
| Front :
IMR 1400 - compact |
|
| OPTIONAL FEATURES |
|
Ambient air temperature probe |
|
NO-measurement (14000 / 14100) |
|
Gas sampling probe with heated
handle |
|
SO2-measurement |
|
Gas sampling probes with different
lengths |
|
NO2-measurement |
|
Electronic controlled soot
measurement |
|
HC-measurement |
|
RS 232 interface |
|
CO-bypass valve with purging
pump |
|
Memory for 200 measurements |
|
12V DC power jack |
|
Draft measurement |
|
|
|
TECHNICAL DATA
| PARAMETER |
PRINCIPLE |
RESOLUTION |
ACCURACY |
RANGE |
STANDARD |
| O2 Oxygen |
Electro-chemical |
0.1 Vol.% |
± 0.2 % |
0-20.9Vol. % |
ü |
| CO Carbon monoxide |
Electro-chemical |
1 ppm |
5 % |
0-2,000ppm |
ü |
| COp Carbon monoxide-corrected |
Calculation |
1
ppm |
5
% |
|
ü |
| NO Nitric oxide |
Electro-chemical |
1 ppm |
5 % |
0-,2000 ppm |
14090/14190 |
| NO2 Nitric dioxide |
Electro-chemical |
1 ppm |
5 % |
0- 100 ppm |
|
| SO2 Sulfur dioxide |
Electro-chemical |
1 ppm |
5 % |
0-4,000 ppm |
|
| HC Hydrocarbons |
|
0.1% |
5 % |
0-100% LEL |
|
| TG Flue gas temperature |
NiCr-Ni thermocouple |
1 K |
± 2 % |
-4° F / 2192°F
-20°C..1200°C |
ü |
| TA Air temperature |
Semiconductor |
1 K |
± 0.5 K |
-4° F / 248° F
-20°C..120°C |
|
| P Draft |
Solid state |
0.004" H2O
0.01 hPa |
± 2 % |
- 12" / 20" H2O
-30hPa/+50hPa |
|
| CO2 Carbon dioxide |
Calculation |
0.1 Vol.% |
± 0.2 % |
0- CO2max |
ü |
| Efficiency / ETA |
Calculation |
1 % |
± 0.5 % |
0-999 % |
ü |
| Losses / qA |
Calculation |
1 % |
± 0.5 % |
0-999 % |
ü |
| Excess Air/LAMBDA |
Calculation |
1 % |
± 2 % |
0-999 % |
ü |
| Soot |
Filter paper method |
|
|
|
|
Other measurement ranges are available
upon request
Equipped with max 4 sensors
| SPECIFICATION |
Dimensions wxdxh:
14000 & 14090: 12"(305)
x 9"(228) x 4.6"(116mm)
14100 & 14190: 16"(425mm)
x 7"(185mm) x 11"(290mm) |
Weight:
14000 & 14090: approx.
6.7lbs. (2.9kg)
14000 & 14090: approx.
15lbs. (5.8kg) |
| MODEL |
PART-NO. |
| IMR 1400-c O2, CO |
14000 |
| IMR 1400-c O2,CO, NO |
14090 |
| IMR 1400-cp O2,CO |
14100 |
| IMR 1400-cp O2,CO, NO |
14190 |
|
| IMR 1400 - compact - printer |
|
|
IMR Environmental Equipment, Inc. reserves the right to
adopt technical modifications without prior notice
IMR Environmental Equipment, Inc.
3634 Central Ave. - St. Petersburg, FL
33711 USA
Phone: 727/328-2818 - Toll free: 1-800-746-4467
Fax: 727/328-2826
Email: Info@imrusa.com
© Copyright
2001 IMR Environmental Equipment, Inc. |