IMR 1400-IR
MEASURES CO2 with NDIR Technology
This latest model does not only measure the most common parameters but also
CO2 !!
- Measures flue-gases of boilers, burners,
engines,..
- Developped to meet the customers need
- High quality combustion gas analyzer using
the latest sensor technology
- Easy to use and it measures all important
parameters
- Includes all needed features for a complete
analysis
|
|
| STANDARD
FEATURES |
|
Illuminated display with
simultaneous display of 8 measured variables |
|
Printout of all measured
and calculated parameters |
|
Gas sampling probe, length 10.5" (270mm),NiCrNi,
flexible hose 11.5 ft. (3,5m) |
|
Languages: D, UK, F, USA,
E, TR, etc. |
|
Electronic controlled soot
measurement |
|
Combustion air probe, length
5" (130mm), line 11.5 ft. (3,5m) |
|
7 programmed and 5 programmable
fuels |
|
Automatic and manual CO overflow
shut-off |
|
Condensation trap with integrated
filter |
|
Measurement display is switchable
between ppm, mg, mg(O2) and mg/kwh |
|
Automatic zero calibration
within 3 minutes. Recalibration within 30 sec. |
|
Operating temperature 50°F..104°F (10°C..40°C) |
|
Battery status is shown on
the measurement display |
|
Integrated self check program
for all functions and parameters. |
|
Storing temperature -4°F..122°F (-20°C..50°C) |
|
Interface RS 232 |
|
After 1000 operating hours
a "Service needed" note appears on the display. |
|
Power supply 230V/50Hz,
110V/60Hz, 12VDC |
|
TECHNICAL DATA
| PARAMETER |
PRINCIPLE |
RESOLUTION |
ACCURACY |
RANGE |
1400 - IR |
| O2 Oxygen |
Electro-chemical |
0.1 Vol.% |
± 0.2 % |
0-20.9Vol. % |
ü
|
CO2 Carbon dioxide
|
NDIR
|
0.01 Vol.%
|
5 %
|
0-30.00Vol. %
|
ü
|
| CO Carbon monoxide |
Electro-chemical |
1 ppm |
5 % |
0-2,000 ppm |
ü
|
| COp Carbon monoxide-corrected |
Calculation |
1 ppm |
5 % |
|
ü |
| NO Nitric oxide |
Electro-chemical |
1 ppm |
5 % |
0-2,000 ppm |
|
| NO2 Nitric dioxide |
Electro-chemical |
1 ppm |
5 % |
0- 100 ppm |
|
| SO2 Sulfur dioxide |
Electro-chemical |
1 ppm |
5 % |
0-4,000 ppm |
|
| HC Hydrocarbon |
Solid state |
0.1% |
5 % |
0-100% LEL |
|
| TG Gas
temperature |
NiCr-Ni thermocouple |
1 K |
± 2 % |
-4°F..2192°F
-20°C..1200°C |
ü
|
| TA Air
temperature. |
Semiconductor |
1 K |
± 0.5 K |
4°F..248°F
-20°C..120°C |
ü
|
| P Draft |
Solid state |
0.004" H2O
0.01 hPa |
± 2 % |
-12"H2O/+20"H2O
-30hPa/+50hPa |
ü
|
| Combustion Efficiency / ETA |
Calculation |
1 % |
± 0.5 % |
0-99,9 % |
ü
|
| Losses / qA |
Calculation |
1 % |
± 0.5 % |
0-99,9 % |
ü
|
| Excess air / LAMBDA |
Calculation |
1 % |
± 2 % |
1,0-9,99 |
ü
|
| Soot |
Filter paper |
|
|
|
ü
|
Other ranges are available upon request. Max. 4 sensors
are possible
Standard: O2-CO-CO2 and one more sensor is optional
available (NO or NO2 or SO2 or HC)
| SPECIFICATION |
| Dimensions wxdxh: 16"(425mm) x 7"(185mm) x 11"(290mm) |
| Weight: approx. 15lbs. (5.8kg) |
| MODEL |
PART-NO. |
| IMR 1400 IR O2,
CO, CO2 |
14296 |
IMR Environmental Equipment, Inc. reserves the right
to adopt technical modifications without prior notice
IMR Environmental Equipment, Inc.
3634 Central Ave. - St. Petersburg, FL
33711 USA
Phone: 727/328-2818 - Toll free: 1-800-746-4467
Fax: 727/328-2826
Email: Info@imrusa.com
© Copyright
2004 IMR Environmental Equipment, Inc.
|