IMR 1400
The combustion gas analyzer
IMR1400CO is easy to use, compact and rugged.
Two CO-sensors are installed, one for low CO-measurements and one for
high measurements.
This helps to get the best possible accuracy for different applications
(e.g. wood fired applications).
Measured parameters:
Oxygen O2, Carbon monoxide CO in ppm, Carbon monoxide CO in Vol.%
Calculated parameters:
Losses, combustion efficiency, excess air, carbon dioxidde
The series IMR1400CO can also measure draft, soot and stack gas
temperature. |
|
| IMR
1400CO-OVERVIEW |
|
Rugged aluminum case with an additional compartment |
|
Memory for 200 measurements |
|
Gas sampling probe with heated handle; type K |
|
Sensors: O2 - CO - CO |
|
Battery status is shown on the display; 6 hrs |
|
Combustion air probe |
|
Illuminated and simultaneous display of 8 values |
|
High speed thermal printer that prints all values
(incl. date and time) |
|
Condensation trap with integrated filter |
|
7 fuels are programmed while 5 more are
programmable |
|
CO-solenoid valve to automaticall switch between
the low and high CO-sensor |
|
Operating temperature 50°F..104°F (10°C..40°C) |
|
Engineering units:
ppm, mg, mg(O2), mg/kWh |
|
Electronic controlled soot measurement |
|
Storing temperature -4°F..122°F (-20°C..50°C) |
|
Interface RS 232 |
|
3 minute zero point calibration with self-check |
|
Power supply 230V/50Hz, 110V/60Hz, 12VDC |
|
TECHNICAL DATA
| PARAMETER |
PRINCIPLE |
RESOLUTION |
ACCURACY |
RANGE |
1400 P |
| O2
Oxygen |
Electro-chemical |
0.1 Vol.% |
±
0.2 % |
0-20.9Vol.
% |
ü
|
| CO
Carbon monoxide |
Electro-chemical |
1 ppm |
Z |
0-2,000
ppm |
ü
|
| CO Carbon monoxide |
Electro-chemical |
1 ppm |
Z |
O-4.000 Vol.% |
ü |
| NO
Nitric oxide |
Electro-chemical |
1 ppm |
Z |
0-2,000
ppm |
optional
|
| NO2
Nitric dioxide |
Electro-chemical |
1 ppm |
Z |
0- 100
ppm |
optional |
| SO2
Sulfur dioxide |
Electro-chemical |
1 ppm |
Z |
0-4,000
ppm |
optional
|
| TG Gas
temperature |
NiCr-Ni
thermocouple |
1 K |
±
2 % |
-4°F..2192°F
-20°C..1200°C |
ü
|
| TA Air
temperature. |
Semiconductor |
1 K |
±
0.5 K |
4°F..248°F
-20°C..120°C |
ü
|
| P Draft |
Solid
state |
0.004" H2O
0.01
hPa |
±
2 % |
-12"H2O/+20"H2O
-30hPa/+50hPa |
ü
|
| CO2
Carbon dioxide |
Calculation |
0.1 Vol.% |
±
0.2 % |
0- CO2
max |
ü
|
| Combustion
Efficiency / ETA |
Calculation |
1 % |
±
0.5 % |
0-99,9 % |
ü
|
| Losses /
qA |
Calculation |
1 % |
±
0.5 % |
0-99,9 % |
ü
|
| Excess
air / LAMBDA |
Calculation |
1 % |
±
2 % |
1,0-9,99 |
ü
|
| Soot |
Filter
paper |
|
|
|
ü
|
Other ranges are available
upon request.
Z= 0-20% of the measuring range +/- 1% of the maximum value
Z= 21-100% of the measuring range +/- 5% of the displayed value.
4 sensors are the maximum
for the IMR 1400 PS (4th sensor can be specified)
| SPECIFICATION |
| Dimensions wxdxh:
16"(425mm) x 7"(185mm) x 11"(290mm) |
| Weight: approx.
15lbs. (5.8kg) |
| MODEL |
PART-NO. |
| IMR 1400 P
O2, CO, CO |
14291 |
IMR Environmental
Equipment, Inc. reserves the right
to adopt technical modifications without prior notice
IMR
Environmental Equipment, Inc.
3634 Central Ave.
- St. Petersburg, FL
33711 USA
Phone: 727/328-2818
- Toll free: 1-800-746-4467
Fax: 727/328-2826
Email: Info@imrusa.com
©